Aquarium equipment usually works unnoticed until one day the filter starts humming, the water turns cloudy or the thermometer shows an unusually high temperature on a hot day. Most of these problems are solved by calmly checking things in order: power and obvious causes first, then media and settings. Here are the common situations and the steps to start with.

Before changing any settings, make sure you measured correctly: half of all odd results are born in the test vial, not in the tank.

— From the editors

How this section works: situations are described in general terms. Unplug the equipment before any hands-on work in the water, and if the cause is electrical, such as a socket, plug or wiring, call an electrician.

Common situations

The filter is noisy or humming.

Most often the noise comes from air in the housing or a dirty impeller. Unplug the filter, check the impeller and its housing, make sure the seal is in place and that the housing is completely full of water. Humming can also come from vibration: put a soft mat under a canister filter and move an internal one away from the glass. If the device hums but does not pump, do not leave it switched on until you have inspected it.

The flow has dropped.

Flow weakens when the sponges, intake or hoses clog up and the impeller gets coated in slime. Unplug the filter, rinse the mechanical media in tank water, clean the hoses with a brush and inspect the impeller. If the flow does not come back, check the assembly against the manual: an upside-down basket or a kinked hose also hold the water back.

The water is cloudy after start-up.

A milky haze in the first days after start-up is common: bacteria are multiplying in the water while the filter is not yet colonised. Do not wash the filter or change all the water at once, test for ammonia and nitrite, and do not overfeed. Grey cloudiness from poorly rinsed substrate usually settles on its own.

There is a film on the glass and plants.

An algae film usually signals an imbalance between light, CO2 and plant nutrition. Check the timer: has the photoperiod become longer, is sunlight falling on the tank? If you inject gas, check the drop checker and bubble counter. Change one thing at a time and write down in the log exactly what you changed.

The water overheats in summer.

Switch off the heater if the room is already hot, shade the tank from direct sun and check how much heat the light gives off. A fan blowing across the water surface and stronger aeration help. A detailed step-by-step plan is further down this page.

A test shows odd readings.

Doubt the test before the water: check the reagents' expiry date, the cleanliness of the vial, the sample volume and the waiting time. Repeat the measurement and, if possible, cross-check it with another kit. If the reading is confirmed, look through the log at what has changed in the tank recently.

If the water overheats in summer

  1. Check the thermometer and heater

    Make sure the thermometer reads correctly and see whether the heater is switching on. In hot weather it is often not needed at all: unplug it, let it cool down in the water, and only then take it out.

  2. Remove outside sources of heat

    Draw the curtains if sunlight falls on the tank, move away equipment that heats up by itself, and air the room during the cooler hours, in the morning and late in the evening.

  3. Reduce heat from the light

    Raise the lid or the light so heat can escape, and if needed temporarily shorten the photoperiod with the timer. LED fixtures heat the water less than old lamps, but their heat still has to go somewhere.

  4. Run a fan over the water

    A small fan pointed along the surface cools the water through evaporation. Top up the evaporated water regularly, mount the fan so it cannot fall into the tank and power it from a circuit protected by an RCD.

  5. Increase aeration

    Warm water holds less oxygen, so increase surface movement with the filter outflow or an air pump. If CO2 is being injected, watch the inhabitants more closely and reduce the gas flow if necessary.

  6. Cool down gradually

    Do not try to bring the temperature down sharply with large cold water changes or ice straight in the tank: a sudden swing is more dangerous than a slowly warm day. If the heat lasts a long time, consider a permanent chiller sized for your tank volume.

  • Guides

    Step-by-step guides: servicing a canister filter, setting the photoperiod, starting CO2 injection, preparing for a water change. Plus the article catalogue.

  • Tools

    Liquid drop tests and strips, a thermometer, a timer and a scheduled socket, a gravel vacuum with a hose and a parameter log: what helps and how to use it.

  • Security

    Water near sockets, a heater out of water, water siphoning back into an air pump, CO2 pressure, overheating cables and leaks into the flat below.

  • Comparisons

    Canister or internal filter, drop tests or strips, pressurised CO2 or a tank without gas injection: the pros, the hassle and who each option suits.

  • Questions

    Answers about the guide, about choosing and setting up equipment, about safety and about routine maintenance of aquarium gear.

Sources

  • Equipment manufacturers' instructions (in general terms)
  • General electrical safety rules (in general terms)
  • Editorial materials of the guide

Everything described here is stated in general terms and reflects the editors' understanding at the time of writing. The design of your particular filter, light or regulator may differ from our description. If the manual for your equipment says otherwise, follow it: it was written specifically for that device.